深圳市知用电子有限公司
ShenZhen ZhiYong Electronics Co., Ltd.
HCPX8030H(30A/DC~120 MHz)
HCPX8030H(30A/DC~120 MHz)

Bandwidth(-3dBDC-120MHz

Rise time 2.92ns



浏览次数:0
说明书: 产品说明书

1. Features and Applications

The HCPX8000 series current probes are high frequency DC/AC active current probes featuring high bandwidth and high accuracy. Operating with our OT7001 smart probe adaptor, HCPX8000 can communicate with most mainstream brand oscilloscopes on the market and set up attenuation ratio, impedance and delay time automatically. This system freed the users from the trouble of setting parameter manually with the third-party probe and achieve the same user experience as those specialized probe. If the users have no need for smart control function, they can also just power this probe with regular adaptor during measurement.


Specification

Electrical characteristics

Small Pliers

Model

HCPX8030(C/D/H)

HCPX8050

HCPX8070

Bandwidth

(-3dB)

HCPX8030

DC-50MHz(Figure1.a)

DC-50MHz

(Figure4)

DC-30MHz

(Figure7)

HCPX8030C

DC-70MHz(Figure1.b)

HCPX8030D

DC-100MHz(Figure1.c)

HCPX8030H

DC-120MHz(Figure1.d)

Rise time

HCPX8030

7ns

7ns

11.6ns

HCPX8030C

5ns

HCPX8030D

3.5ns

HCPX8030H

2.92ns

Continuous

maximum input

range

HCPX8030

30ArmsFigure2.a

50Arms

(Figure5)

70Arms

(Figure8)

HCPX8030C

30ArmsFigure2.b

HCPX8030D

30ArmsFigure2.c

HCPX8030H

30ArmsFigure2.d

Max peak current value

50Apk

75Apk

100Apk

Range

5A

1X

7.5A

1X

10A

2X

30A

10X

50A

10X

70A

20X

Overload

5A

5APk

7.5A

7.5APk

10A

10APk

30A

50APk

50A

75APk

70A

100APk

Current transfer ratio

5A

1V/A

7.5A

1V/A

10A

0.5V/A

30A

0.1V/A

50A

0.1V/A

70A

0.05V/A

measurable

current

5A

1mA

7.5A

1mA

10A

2mA

30A

10mA

50A

10mA

70A

20mA

Amplitude

accuracy (DC,45-66Hz )

5A

±1%±1mA

7.5A

±1%±1mA

10A

±1%±2mA

30A

±1%±10mA

50A

±1%±10mA

70A

±1%±20mA

Input

impedance

HCPX8030

Reference Figure3.a

Reference (Figure6)

Reference (Figure9)

HCPX8030C

Reference Figure3.b

HCPX8030D

Reference Figure3.c

HCPX8030H

Reference Figure3.d

Terminal load

≥100kΩ

Power supply

DC 5V/2AStandard Adaptor

Voltage of insulated wire

300V CAT I *

Safety compliance

EN61010-1: 2010+A1:2019  EN 61010-2-032:2019

EMC standard

EN61326-1:2013  EN61000-3-2:2014  EN61000-3-3:2013